The Dreno AP Series S is intended for domestic use, as demonstrated by its compact size achieved by a pump body cast together with the electromechanical unit, convenient handling permitted by its light weight and easy carrying handle, and the versatility permitted by the generous starting torque and operation of its motors.

GENERAL INFORMATION ON ELECTROMECHANICAL UNIT

Test voltage and frequency

Single phase : 220 ÷ 240 Volt - 50 Hz

Three phase : 380 ÷ 415 Volt - 50 Hz

Direction of rotation

Clockwise seen from top of the pump

Type of impregnation

Double impregnated humidity-resistant winding

Type of motor winding (Single phase)

Induction motor with dry winding and automatic thermal protection

Type of motor winding (Three phase)

Induction motor with dry winding and automatic thermal protection


LIST OF MATERIALS / PAINTING

Motor cable 10 meters

H07RN-F

Nuts and bolts

A2 steel

Electromechanical unit

EN-GJL-250 cast iron

Paint

Ecological epoxy vinyl

Hydraulic unit and impeller

EN-GJL-250 cast iron

Motor Shaft

X30Cr13 (AISI420) stainless steel


LIMITS ON USE AND APPLICABLE STANDARDS

Max. liquid temperature

40ºC

Max. immersion depth

20m


LIMITS ON USE AND APPLICABLE STANDARDS

Max. liquid temperature

40ºC

Max. immersion depth

20m


Type of Pump

Absorption

Type of Pump

Absorption

Power

Poles

R.p.m

Outlet BSP

Free passage

Single Phase

A

Three Phase

A

kW

 

min

Ø mm

H/V

Ø mm

APS 100/2M

6,6

APS 100/2T

2,1

0,9

2

2900

40

? H

10


Power Range

0.9kw

DN Outlet Range

40mm BSP

Poles / R.p.m.

2 / 2900

Max. Head

20,3m

Max. Capacity

5,2 l/sec
18,7m ³ /h


SPECIFICATIONS

Upper and lower permanently lubricated ball bearings

Class F Motor Insulation

Thermistor, capacitor and float - standard on all single phase models

Thermistor and Relay standard on all Three Phase models

1 Mechanical Seal silicon carbide (viton) and 1 lip seal


OVERALL DIMENTIONS
JCR
PAGE 3
of 3

 
 
 
 
 
 
Copyright © Mc Bean’s
 